Dell Precision workstations with PCoIP Zero Clients enable remote access from anywhere.
Dell's quick reference guide describes a 1:1 remote-access setup that connects a Dell Precision workstation equipped with a PCoIP remote access host card to a Wyse or Amulet Hotkey DXZ4 PCoIP Zero Client over a LAN/WAN. It lists the Precision 3930 Rack, 7920 Rack and 3000, 5000 and 7000 Tower workstations, and notes Teradici PCoIP software client options.
The guide covers installing the half height dual display host card, connecting Mini DisplayPort, Category 5e Ethernet and management-computer cables, and configuring the host card and zero client through their web interfaces. It includes default IP addresses and passwords and ends with Dell contact information.
| Default host card IP address | 192.168.1.100 |
|---|---|
| Host card default password | None |
| Management computer IP address and subnet mask | 192.168.1.200 / 255.255.0.0 |
| Default zero client IP address | 192.168.1.50 |
| Default Wyse Zero client password | Administrator |
| Default Amulet DXZ4 Zero Client password | ahkdante |
The default IP address for the host card is 192.168.1.100.
There is no default password on the host card. Leave the Idle Timeout field set to Never and click Log In.
The default password for Wyse Zero clients is Administrator.
The default password for the Amulet DXZ4 Zero Client is ahkdante.