This document describes the assembly instructions for the PowerLokTM 10.0 single-pole right-angle plug. The product features include: 1. Shielded design to prevent electromagnetic interference; 2. High-voltage interlock design to prevent mishandling; 3. High-quality materials to ensure product quality.
This Amphenol PowerLokTM 10.0 1POS 90D assembly manual provides instructions for the right angle plug connector, covering both shielding and unshielding versions. It applies to manual P/N 8P1082 Rev.06 and lists plug type, key and color options, series, and supported cable sizes.
The document details cable selection and strip lengths, component loading order, terminal crimping, shielding braid preparation, and back shell assembly with a tightening torque of 10~12 N.m. It also specifies obligatory insulation resistance and dielectric withstand voltage test parameters, plus an appendix with cable crimping reference specifications. This manual is written in Chinese.
| Shell tightening torque | 10~12 N.m |
|---|---|
| Strip length A | 18±1 mm |
| Strip length B | 27±1 mm |
| Insulation resistance cable to shell | 1000 V DC > 500 MΩ |
| Dielectric withstand cable to shell | 5000 V DC < 5 mA |
The shell should be screwed up with a torque of 10~12 N.m to finish assembly.
For 35 mm², 50 mm², and 70 mm² cables, strip length A is 18±1 mm and B is 27±1 mm.
Cable to shell and cable to HVIL are tested at 1000 V DC with resistance greater than 500 MΩ; HVIL to shell requires greater than 100 MΩ.
Flip over the shielding braid and cut it into a length of 20 mm.