Amphenol PowerLokTM 10.0 1POS 90D Plug Assembly Manual

This document describes the assembly instructions for the PowerLokTM 10.0 single-pole right-angle plug. The product features include: 1. Shielded design to prevent electromagnetic interference; 2. High-voltage interlock design to prevent mishandling; 3. High-quality materials to ensure product quality.


Amphenol PowerLokTM 10.0 1POS 90D Plug Assembly Manual - cover page
Brand
Amphenol
Category
Other Electronics
Document type
Installation Guide
Language
Chinese
Pages
9
File format
PDF
File size
688 KB
Published
20 November, 2023
Updated
20 November, 2023
MD5 checksum
F24878DD5AFD0BB4C57910A03BAC4D5B

About this manual

This Amphenol PowerLokTM 10.0 1POS 90D assembly manual provides instructions for the right angle plug connector, covering both shielding and unshielding versions. It applies to manual P/N 8P1082 Rev.06 and lists plug type, key and color options, series, and supported cable sizes.

The document details cable selection and strip lengths, component loading order, terminal crimping, shielding braid preparation, and back shell assembly with a tightening torque of 10~12 N.m. It also specifies obligatory insulation resistance and dielectric withstand voltage test parameters, plus an appendix with cable crimping reference specifications. This manual is written in Chinese.

What's inside

  • Assembly Instruction
  • Strip length
  • Terminal crimping
  • Shielding braid preparation
  • Back shell assembly
  • Insulation Resistance Test
  • Dielectric Withstand Voltage Test
  • Cable crimping reference specification

Specifications

Shell tightening torque10~12 N.m
Strip length A18±1 mm
Strip length B27±1 mm
Insulation resistance cable to shell1000 V DC > 500 MΩ
Dielectric withstand cable to shell5000 V DC < 5 mA

Frequently asked questions

What is the required back shell tightening torque?

The shell should be screwed up with a torque of 10~12 N.m to finish assembly.

What cable sizes does the PowerLokTM 10.0 plug support?

For 35 mm², 50 mm², and 70 mm² cables, strip length A is 18±1 mm and B is 27±1 mm.

What are the insulation resistance test requirements?

Cable to shell and cable to HVIL are tested at 1000 V DC with resistance greater than 500 MΩ; HVIL to shell requires greater than 100 MΩ.

How long should the shielding braid be cut?

Flip over the shielding braid and cut it into a length of 20 mm.