Amphenol PowerLokTM10.0 1POS 90D Plug Assembly Manual
This manual provides assembly instructions for the Amphenol PowerLokTM10.0 1POS 90D plug, available in shielded and unshielded configurations. It details the selection of appropriate cables, stripping lengths, and the step-by-step loading of components including terminals, insulation sleeves, and metal shells. This manual is written in Chinese.
Read onlineAmphenol 10.0 1POS 90D specifications
| Plug Type | Right angle |
|---|---|
| Core Count | 1POS |
| Torque Specification | 10 -12N.m |
| Insulation Resistance Test Voltage | 1000 VDC |
| Dielectric Withstand Voltage Test Voltage | 5000 VDC |
Source: Amphenol PowerLokTM10.0 1POS 90D Plug Assembly Manual
All Amphenol 10.0 1POS 90D documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in these manuals
What threadlocker is recommended for the fastening screw?
It is recommended to use low strength threadlocker LOCTITE 222.
What is the required torque for tightening the metal shell?
The metal shell should be screwed up with a torque of 10 -12N.m.
What is the required back shell tightening torque?
The shell should be screwed up with a torque of 10~12 N.m to finish assembly.
From: Amphenol PowerLokTM 10.0 1POS 90D Plug Assembly Manual
What cable sizes does the PowerLokTM 10.0 plug support?
For 35 mm², 50 mm², and 70 mm² cables, strip length A is 18±1 mm and B is 27±1 mm.
From: Amphenol PowerLokTM 10.0 1POS 90D Plug Assembly Manual