AMI-250 single-phase grid-connected photovoltaic microinverter installation and user manual
This manual describes the Acrel AMI-250 single-phase grid-connected photovoltaic microinverter, which uses DSP control, has one DC input, performs MPPT control, and communicates via power-line carrier technology.
It provides technical parameters, dimensions, required tools, safety and installation notes, installation and replacement steps, operating status, maintenance and troubleshooting guidance, and single-phase and three-phase wiring diagrams. This manual is written in Chinese.
| Maximum operating voltage (PV side) | 50 V |
|---|---|
| Maximum withstand voltage (PV side) | 56 V |
| MPPT voltage range | 28-45 V |
| Input startup voltage | 28 V |
| Input shutdown voltage | 20 V |
| Maximum input current | 10 A |
| MPPT efficiency | >99% |
| Maximum input power | 250 W |
| Operating voltage range (AC side) | 210-265 V |
| Maximum withstand voltage (AC side) | 270 V |
| Operating frequency range | 49.5-50.5 Hz |
| Normal output current | 1 A |
| Maximum output current | 1.2 A |
| AC power | 235 W |
| Power factor | >0.99 |
| Output current THD | <5% |
| Maximum efficiency | 94.5% |
| Nighttime self-consumption | <0.25 W |
| Operating ambient temperature | -40 to +65 C |
| Storage temperature | -40 to +80 C |
| Protection rating | IP65 |
| Dimensions | 260*160*40 |
| Cooling method | Natural cooling without fan |
No more than 16 microinverters can be connected on one branch.
The microinverter and PV panel must be separated by at least 2 cm.
The system starts generating power 3 minutes after the breakers are closed.
When DC power is applied, the indicator light turns red and then flashes green, indicating normal startup.