This document describes the features and specifications of the MOTOGERADOR BFG 4T-MOD.
This Portuguese-language instruction manual covers the Buffalo BFG 4T gasoline motogenerators (models BFG 2500 STD, BFG/BFGE 2500, BFG 3250, BFG/BFGE 6500 and BFGE 6500 Trifásico 380V). It opens with safety procedures covering fire extinguishers, electric shock, carbon monoxide poisoning, battery acid and hot exhaust parts, followed by guidance on handling and lifting the unit, electrical connections, and battery care.
The manual then shows the component locations on the panel, explains fuel filling with common gasoline and engine oil filling with SAE 20W50, and gives the technical characteristics table (power, tank capacity, autonomy, starting system, noise, dimensions). It closes with AC and DC operation instructions, circuit breaker ratings, air filter and cooling maintenance, and a troubleshooting flow chart. This manual is written in Portuguese.
| Engine (BFG 2500, 2500 STD, 3250) | Buffalo 6.5cv / 7.0cv, 4-stroke, gasoline |
|---|---|
| Engine (BFG 6500, BFGE 6500 Trifásico 380V) | Buffalo 13cv, 4-stroke, gasoline |
| Maximum power | 2.2 kW (2500 / 2500 STD), 3.25 kW (3250), 5.5 kW (6500) |
| Nominal power | 2.0 kW (2500 / 2500 STD), 3.0 kW (3250), 5.0 kW (6500) |
| Output frequency | 60 Hz |
| Voltage control | AVR / brush |
| Fuel tank capacity | 3.6 L (2500 STD), 15 L (2500, 3250), 25 L (6500) |
| Runtime at 50% load | 2.5 h (2500 STD), 12 h (2500), 11 h (3250), 9 h (6500) |
| Starting system | Manual on BFG models, electric on BFGE models |
| Noise at 7 m | 68 dB(A) (2500 / 2500 STD / 3250), 76 dB(A) (6500) |
| Dimensions (L x W x H) | 475x410x410 mm (2500 / 2500 STD / 3250), 715x480x620 mm (6500) |
| Circuit breaker current | 10 A (2500 / 2500 STD), 13.5 A (3250), 26 A (6500), 11.3 A (6500 Trifásico) |
| Battery charger output | 12V; 8.3A on models that have it |
| Engine oil | SAE 20W50, API SF-SG-SH-SJ; 600 ml (2500/3250) or 1,100 ml (6500) |
Use SAE 20W50 lubricating oil meeting API SF-SG-SH-SJ. Fill 600 ml on the BFG(E) 2500/2500 STD and BFG 3250, and 1,100 ml on the BFG(E) 6500 and BFGE 6500 Trifásico.
Common gasoline, filled with the engine off and using a funnel; avoid spilling fuel on the engine surface.
Every 150 hours of use regardless of conditions, or every 50 hours and cleaned daily in very dusty conditions.
Only for charging 12V – 8.3A batteries, connecting the red plug to positive (+) and the black plug to negative (-).
The manual states the engine should always run at the recommended speed of 3,600 RPM.