Thermo Fisher Scientific Ion 540 Kit - OT2 User Guide

The Ion 540™ Kit is a reagent kit for template preparation, chip loading, and sequencing for use with the Ion OneTouch™ 2 System, Ion S5™ System, Ion S5™ XL System, Ion GeneStudio™ S5 System, Ion GeneStudio™ S5 Plus System, and Ion GeneStudio™ S5 Prime System.


Thermo Fisher Scientific Ion 540 Kit - OT2 User Guide - cover page
Brand
Thermo Fisher Scientific
Category
Other products
Document type
User Manual
Language
English
Pages
83
File format
PDF
File size
2.7 MB
Published
11 November, 2023
Updated
11 November, 2023
MD5 checksum
3359D3E17F3D506E36CE6B7C3594A20F

About this manual

This user guide (Publication Number MAN0010850, Revision E.0) provides instructions for template preparation, chip loading, and sequencing with the Ion 540 Kit - OT2 from Thermo Fisher Scientific. The kit is used with the Ion OneTouch 2 System and with the Ion S5, Ion S5 XL, and Ion GeneStudio S5 series sequencers.

The Ion 540 Kit - OT2 contains the reagents and materials required to prepare enriched, template-positive Ion Sphere Particles, load them on an Ion 540 Chip, and sequence the loaded chips. Each kit supplies enough material for 8 reactions of enriched, template-positive ISPs and for loading and sequencing 8 chips. The guide covers instrument setup, creating a Planned Run in Torrent Suite Software, the OneTouch 2 and ES procedures, sequencer initialization, chip loading, starting the sequencing run, troubleshooting, and safety.

What's inside

  • Product information
  • Before you begin
  • Create a Planned Run
  • Prepare template-positive Ion 540 ISPs
  • Enrich the template-positive Ion 540 ISPs
  • Initialize the sequencer
  • Load the Ion 540 Chip
  • Start the sequencing run
  • Troubleshooting
  • Safety

Specifications

Catalog numberA27753
Reactions per kit8 reactions of enriched, template-positive ISPs; 8 chips
Library read lengthUp to 200-base-read libraries
Sequencer initializations4 (2 sequencing runs per initialization)
Software compatibilityTorrent Suite Software 5.2 and later
Ion S5 Reagent Mix storageShipped at -30°C to -10°C; store thawed Master Mix at 2°C to 8°C
Ion OneTouch Oil450 mL, 15°C to 30°C

Frequently asked questions

Which sequencers is the Ion 540 Kit - OT2 compatible with?

It is used with the Ion S5 Sequencer, Ion S5 XL Sequencer, and Ion GeneStudio S5 Series Sequencers (Ion GeneStudio S5, S5 Plus, and S5 Prime Systems).

How many reactions and chips does one Ion 540 Kit - OT2 cover?

Each kit contains the supplies required to prepare 8 reactions of enriched, template-positive ISPs, then load and sequence 8 chips.

Which Torrent Suite Software version works with the Ion 540 Kit - OT2?

The kit is compatible with Torrent Suite Software 5.2 and later, and the software should be updated to the latest available version before use.

Can the Ion 540 Kit - OT2 be used with the original Ion OneTouch System?

No. The kit must only be used with the Ion OneTouch 2 System and this user guide, not with the Ion OneTouch System.