Toray has released a new reverse osmosis membrane, model TM710FR. This membrane is characterized by its resistance to fouling and high desalting rate, making it ideal for use in the water treatment industry.
This is Toray's product information bulletin for the TM710FR, a fouling resistant and high rejection reverse osmosis membrane element. It gives the membrane type, test conditions, minimum salt rejection and minimum product flow rate, together with the element dimensions and flow direction through the feed spacer.
The second page lists the operating limits for the element, including maximum operating pressure, maximum feed water temperature, feed water pH range and maximum pressure drop per element and per vessel. It also contains operating information notices on storage solution, oxidizing agents and first-hour permeate, and contact addresses for Toray membrane offices in Asia and Oceania, the Americas, Europe and China. The bulletin is dated MAR. 2019.
| Membrane Type | Cross Linked Fully Aromatic Polyamide Composite |
|---|---|
| Minimum Salt Rejection | 99.65% |
| Minimum Product Flow Rate | 2,150 gpd (8.2 m3/d) |
| Element Diameter / Membrane Area / Nominal Salt Rejection / Nominal Product Flow Rate / Feed Spacer Thickness | 4 inch; 87 ft2 (8 m2); 99.8%; 2,600 gpd (9.8 m3/d); 31 mil |
| Test Feed Water Pressure | 225 psi (1.55 MPa) |
| Test Feed Water Concentration | 2,000 mg/l NaCl |
| Maximum Operating Pressure | 600 psi (4.1 MPa) |
| Maximum Feed Water Temperature | 113 °F (45 °C) |
| Maximum Pressure Drop per Element | 15 psi (0.10 MPa) |
| Maximum Pressure Drop per Vessel | 50 psi (0.34 MPa) |
The minimum salt rejection is 99.65%, while the nominal salt rejection listed is 99.8%.
Permeate from the first hour of operation shall be discarded.
The maximum feed water temperature is 113 °F (45 °C).
Free chlorine and other oxidizing agents can cause unexpected oxidation of the membrane, so they should be removed before operating the RO system.