Toray BWRO TM700 Series TM710 TM720-370 TM720-400 TM720-440 Product Information Bulletin

Product information bulletin for Toray BWRO TM700 series membrane elements, detailing specifications, operating limits, and handling instructions.


Toray BWRO TM700 Series TM710 TM720-370 TM720-400 TM720-440 Product Information Bulletin - cover page
Brand
Toray
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
2
File format
PDF
File size
72 KB
Published
28 October, 2026
Updated
28 October, 2026
MD5 checksum
11E6E0A3496543AD0385D157FB95B03A

About this manual

This document provides technical specifications for the Toray BWRO TM700 series reverse osmosis membrane elements, including models TM710, TM720-370, TM720-400, and TM720-440. It lists key performance metrics such as membrane type, salt rejection rates, product flow rates, and physical dimensions for each model.

What's inside

  • Membrane Type
  • Test Conditions
  • Minimum Salt Rejection
  • Minimum Product Flow Rate
  • Dimensions
  • Operating Limits
  • Storage and Handling
  • Operating Information

Specifications

Membrane TypeCross Linked Fully Aromatic Polyamide Composite
Minimum Salt Rejection99.0%

Frequently asked questions

What is the recommended storage solution for Toray elements?

It is recommended to immerse Toray elements in a protective solution containing 500 -1,000 ppm of sodium bisulfite (food grade) dissolved in permeate.

What should be done with the permeate from the first hour of operation?

The permeate from the first hour of operation shall be discarded.

What causes unexpected oxidation of the membrane?

The presence of free chlorine and other oxidizing agents, especially when heavy metals act as oxidation catalysts in the feed water.