Toray High Rejection BWRO Membrane TM710D/TM720D Series

Technical specs and operating guidelines for Toray's high-rejection BWRO membranes, including TM710D and TM720D variants.


Toray High Rejection BWRO Membrane TM710D/TM720D Series - cover page
Brand
Toray
Document type
Product Leaflet
Language
Chinese
Pages
2
File format
PDF
File size
72 KB
Published
08 November, 2026
Updated
08 November, 2026
MD5 checksum
1BFF0EACA7B9A1A98B151CFF6B6E71E3

About this manual

This document details the technical specifications and operating limits for Toray's high-rejection BWRO membranes, including models TM710D, TM720DA400, TM720D-400, and TM720D-440. It covers membrane dimensions, salt rejection rates, product flow rates, and maximum operating conditions. The document also includes storage, handling, and chemical compatibility guidelines to ensure proper system operation and warranty validity.

Key operational parameters include maximum feed water temperature (113°F/45°C), maximum pressure (600 psi/4.1 MPa), and recommended feed water pH ranges (2–11 for continuous operation, 1–13 for chemical cleaning). Users are advised to consult Toray’s technical bulletins or contact specialists for design applications. This manual is written in Chinese.

What's inside

  • Membrane Type
  • Test Conditions
  • Minimum Salt Rejection
  • Product Flow Rate
  • Dimensions
  • Operating Limits
  • Storage and Handling
  • Chemical Compatibility
  • Warranty Conditions

Specifications

Membrane TypeCross Linked Fully Aromatic Polyamide Composite
Minimum Salt Rejection99.65%
Product Flow Rate - TM710D2,150 gpd (8.2 m3/d)

Frequently asked questions

What is the minimum salt rejection rate for these membranes?

The minimum salt rejection rate is 99.65%.

What should be done to prevent biological growth during short-term storage?

Immerse the elements in a protective solution containing 500–1,000 ppm of sodium bisulfite (food grade) dissolved in permeate.