Technical specs and operating guidelines for Toray's high-rejection BWRO membranes, including TM710D and TM720D variants.
This document details the technical specifications and operating limits for Toray's high-rejection BWRO membranes, including models TM710D, TM720DA400, TM720D-400, and TM720D-440. It covers membrane dimensions, salt rejection rates, product flow rates, and maximum operating conditions. The document also includes storage, handling, and chemical compatibility guidelines to ensure proper system operation and warranty validity.
Key operational parameters include maximum feed water temperature (113°F/45°C), maximum pressure (600 psi/4.1 MPa), and recommended feed water pH ranges (2–11 for continuous operation, 1–13 for chemical cleaning). Users are advised to consult Toray’s technical bulletins or contact specialists for design applications. This manual is written in Chinese.
| Membrane Type | Cross Linked Fully Aromatic Polyamide Composite |
|---|---|
| Minimum Salt Rejection | 99.65% |
| Product Flow Rate - TM710D | 2,150 gpd (8.2 m3/d) |
The minimum salt rejection rate is 99.65%.
Immerse the elements in a protective solution containing 500–1,000 ppm of sodium bisulfite (food grade) dissolved in permeate.