The valve island adapter manual introduces the model, parameters, interface diagram, wiring method and other information of the valve island adapter.
This is a bilingual Chinese/English instruction manual (说明书 / manual) for IO-Link valve island adapters supplied under the ordering codes 00BL11, 00BM11, 00BN11 and 00BP11, each with its own part number. Section 1 gives a model and parameter table covering output signal, port, IO-Link data length, cycle time, working and storage temperature, housing material, size and cable length for the four versions, and the table also shows the adapter used with Festo CPV, Bosch Rexroth LS04/HF04 and SMC VQC series valve islands.
Section 2 shows the IO-Link interface diagram for the M12 class A male connector with its pin assignments, indicator lights and transmission rate. Section 3 explains the process data / output data layout for the 4-byte versions (00BM11, 00BP11) and the 2-byte versions (00BL11, 00BN11) with byte and bit addressing examples, and section 4 gives the 25-pin SUB-D pin distribution and the pin-to-point relationships in figures 5 to 7. This manual is written in Chinese.
| Output signal | IO-Link |
|---|---|
| Port | SUB-D 25-pin |
| IO-Link data length | 2 bytes or 4 bytes depending on model |
| Cycle time | 3 ms or 10 ms depending on model |
| Working temperature | -25 to +70 °C |
| Storage temperature | -25 to +85 °C |
| Housing material | Plastic |
| Length of cable with M12 connector | 60 cm |
| Degree of protection | IP40 |
| Transmission rate | COM2, 384 kbaud |
The adapter provides an IO-Link output signal.
It has a SUB-D 25-pin port.
The listed degree of protection is IP40.
The cable with the M12 connector is 60 cm long.