This product is a laser cutting machine for cloth, with a wavelength of 10.6μm, a maximum power of 100W and an angle of 3.1mrad.
This is the Chinese-language instruction manual (使用说明书) for the laser specification units PS900SB13090CKZ and PS900SB13090CKW. The laser is a Class 4 device (等级 4, 禁止目视) with a wavelength of 10.6 µm and a maximum power of 100 W, used for cutting cloth, and it is intended to be installed on a machine; the manual instructs users to read the safety precautions of the host machine's manual before installation.
The manual covers safety precautions for installation, adjustment and use, maintenance instructions including lens care, electrical safety with circuit diagrams, installation of the laser power supply, operating instructions (power-on, air supply, pause handling, chiller use, laser adjustment and use, fan airflow adjustment, pattern and layer editing, speed settings), precautions for use in winter or cold regions, and identification and handling of common faults such as high-voltage arcing, laser tube breakage and power attenuation. This manual is written in Chinese.
| Laser class | Class 4, not to be viewed directly |
|---|---|
| Wavelength | 10.6 µm |
| Maximum power | 100 W |
| Divergence angle | 3.1 mrad |
| Working air pressure | 0.5–0.55 MPa minimum, checked daily |
| Cooling water temperature | 15–25 °C |
| Cooling water flow rate | 8–13 L/min |
| Cooling water type | Soft water (bottled or purified water), about 5–6 L, changed every 3 months |
| Laser tube life | About 6 months |
| Focus mirror and reflector life | About 1 year, cleaned regularly |
Goggles must be worn and must meet the stated conditions: CC certification, visible light transmittance VLT > 60%, absorbing or reflecting CO2 laser protection at 10.6 µm with protection level OD5+, or be supplied by the manufacturer.
Causes include water freezing inside the laser at low temperature, no water flow, or water not filling the cooling jacket so parts overheat. Use a water chiller, keep water temperature at 15–25 °C, and mount the tube with the marked side up at the supporting points.
On power supplies with a test function, press the test switch in standby: if the laser lamp does not light the power supply is faulty; if it lights but no laser is output, the laser is faulty. On supplies without test, jumper W–I and IN–P–G: current above 10 mA with weak or no output means the laser is faulty, current below 10 mA means the power supply is faulty.
Replace the purified water in the laser tube cooling tank about every 3 months, using about 5–6 L of commercially available purified water, and also replace it whenever the laser tube is replaced.