The document describes the Fisher™ 3610J and 3620J positioners and the 3622 electro-pneumatic transducer.
This Portuguese instruction manual D200149X0BR covers the Fisher 3610J and 3620J positioners, including the 3610J, 3610JP, 3611JP, 3620J, 3620JP, and 3621JP variants, plus field installation information for the 3622 electro-pneumatic converter. It addresses installation, operation, calibration, maintenance, and parts ordering.
The pneumatic 3610J/3610JP and electro-pneumatic 3620J/3620JP positioners are described for use with rotary diaphragm and rotary piston actuators; the 3611JP and 3621JP are described for Fisher 585, 585R, 585C, and 585CR or other sliding-stem actuators. The manual also lists specifications, pressure and electrical connections, and related safety information. This manual is written in Portuguese.
| Input signal, 3610J/3610JP/3611JP | 0.2 to 1.0 bar (3 to 15 psig), 0.4 to 2.0 bar (6 to 30 psig), or split range |
|---|---|
| Input signal, 3620J/3620JP/3621JP | 4 to 20 mA DC constant current; maximum compliance voltage 30 V DC |
| Maximum supply pressure | 10.3 bar (150 psig) or the actuator maximum pressure rating, whichever is lower |
| Pressure connections | 1/4 NPT internal |
| Electrical connection, 3620J/3620JP/3621JP | 1/2-14 NPT conduit connection |
| Maximum steady-state air consumption, 3610J | 0.40 m³/h normal (15 scfh) at 1.4 bar (20 psig) supply |
| Supply medium | Air or natural gas |
| Natural gas approval, 3620J/3620JP/3621JP | Not approved for use with natural gas as supply medium |
They use a 4 to 20 mA DC constant current signal, with a maximum compliance voltage of 30 V DC.
The maximum is 10.3 bar (150 psig) or the actuator maximum pressure rating, whichever is lower.
The pressure connections are 1/4 NPT internal connections.
No. These positioners are not approved for use with natural gas as the supply medium.