The PDS23 Solar Water Pump Controller User Manual provides detailed instructions on the installation, operation, maintenance and inspection of the PDS23 Solar Water Pump Controller.
This user manual describes the PDS23 series solar water pump controller, a variable-speed motor drive that converts the high-voltage DC output of a solar array into AC to run a standard three-phase asynchronous motor and supply water in remote areas. It explains the working principle of the solar pumping system, its main components (solar modules, DC breaker or isolator, controller, pump and optional water-level switches), and its features such as smooth motor starting, continuous system diagnostics, over-temperature monitoring and automatic restart after a fault clears.
The manual then covers the controller's general information and parameter tables, dimensions, mechanical and electrical installation, the keypad and commissioning procedure, running-status displays and user parameters, fault codes and common troubleshooting, and periodic maintenance of the controller, pump, solar array and cables. A final chapter explains how to switch the input manually to a backup AC supply (grid or diesel generator), and record forms for the system, installation and solar array are appended. This manual is written in Chinese.
| Power input options | 220 VAC single-phase or 380 VAC three-phase, depending on model |
|---|---|
| Motor type | Standard three-phase asynchronous motor complying with IEC standards |
| Full-power ambient temperature | Up to 45 °C (output power is reduced above 45 °C) |
| Water level switch inputs | 2 (optional) |
| Maximum dry-run time for rotation test | 15 s |
| Restart delay after shutdown caused by shading | 120 s |
| Wait time after power-off before maintenance | At least 10 minutes |
| Check valve spacing in output pipe | Every 30 m (100 ft) of vertical pipe |
It is designed as an adjustable-speed drive for standard three-phase asynchronous motors that comply with IEC standards.
No. The system has no battery or other energy storage, so water is normally pumped into a storage tank for later use.
The water-level switches are optional; if no probe is used, the controller terminals must be short-circuited.
Yes, the input can be switched manually to a backup AC source such as the local grid or a diesel generator, but only one source may be connected at a time and the DC and AC switches must be interlocked.