LaserLinkⓇ LLNTR Fiber Optic Transmitter 1550nm, 5-210 MHz INSTALLATION AND OPERATION MANUAL
This manual describes installation and operation of the LaserLink Narrowcast Return Transmitter (LLNTR) from ANTEC Network Technologies, document 70285, First Edition 12/98. It is organized into three chapters covering general information, installation, and setup and operation, with a table of contents listing safety, equipment description and specifications, unpacking and inspection, care and cleaning of optical connectors, controls and indicators, status monitoring, and troubleshooting.
The manual gives the transmitter's optical, RF, power and physical specifications, explains activation and front panel controls and rear panel connectors, describes status monitoring through the user panel, EMIC or third party systems, and includes a troubleshooting chart for the Power, Optical Power, Laser Temp, Laser Bias and Fan LEDs. It also lists contact information for ANTEC Technical Service and ANTEC offices.
| Output power | +9 ±1 dBm |
|---|---|
| Wavelength | 1550.92 ±0.1 nm (one of eight listed wavelengths) |
| Optical connector | SC/APC |
| Connector return loss | >65 dB SC/APC |
| Frequency range | 5-210 MHz |
| Input and test point impedances | 75 Ohms |
| Flatness | ±0.75 dB |
| Input level | +32 dBmV per channel |
| Level adjustment | -8 to +2 dB |
| Input power | +24 V dc provided by Laser Link II Mainframe |
| Power consumption | 20 W maximum |
| Current drain | 850 mA maximum |
| Operating temperature | 32 to 122 ºF (0 to 50 ºC) |
| Relative humidity | 5 to 95%, non-condensing |
| Dimensions | Height 5.21 in (13.2 cm), width 2.17 in (5.5 cm), depth 13.5 in (34.3 cm) |
| Weight | 2.19 lb (1 kg) |
The RF frequency range is 5-210 MHz, with a flatness of ±0.75 dB.
It takes +24 V dc input power from the Laser Link II Mainframe, drawing 850 mA maximum.
Check the +24 V A and B LED status on the user panel and follow the recommended actions in the troubleshooting chart, contacting Technical Services for an RR#.
The manual states there is no recommended maintenance required to be performed on the LLNTR; performance can be monitored from the front panel diagnostics or element management systems.