SICK STR1-SASM03P5 Non-contact Safety Switch Datasheet

STR1-SASM03P5 is a non-contact safety switch produced by SICK company. This switch has safety integrity level SIL3 (IEC 61508), category 4 (EN ISO 13849), performance level PLe (EN ISO 13849) and other characteristics.


SICK STR1-SASM03P5 Non-contact Safety Switch Datasheet - cover page
Brand
SICK
Category
switch
Document type
Datasheet
Language
Chinese
Pages
7
File format
PDF
File size
523 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
9FE3050F3F12F7E769D9DA18F9B41924

About this manual

The STR1-SASM03P5 is a non-contact safety switch from the SICK STR1 series. This Chinese-language online data sheet lists product features and safety-related parameters, including sensor principle, safety outputs, auxiliary output, safety integrity level, category and performance level.

It also gives electrical, mechanical and environmental specifications, dimension drawings, approach diagrams, a wiring diagram and a list of accessories. The wiring diagram identifies brown, white, blue, black and grey conductors. This manual is written in Chinese.

What's inside

  • Technical data
  • Product features
  • System hardware
  • Sensor principle
  • Safety-related parameters
  • Electrical data
  • Mechanical data
  • Environmental data
  • Connection diagram
  • Accessories

Specifications

Safety integrity levelSIL3 (IEC 61508), SILCL3 (EN 62061)
CategoryCategory 4 (EN ISO 13849)
Performance levelPL e (EN ISO 13849)
Mission time TM20 years (EN ISO 13849)
Supply voltage24 V DC (19.2 V DC to 28.8 V DC)
Dimensions40 mm x 18 mm x 26 mm
Housing materialVISTAL
Enclosure protectionIP67 (EN 60529); IPX9K (ISO 20653)
Operating temperature-10 °C to +70 °C
Shock resistance30 g, 11 ms (IEC 60068-2-27)

Frequently asked questions

What supply voltage does the STR1-SASM03P5 use?

It uses 24 V DC, with a stated supply range of 19.2 V DC to 28.8 V DC.

What safety integrity level does the STR1-SASM03P5 meet?

It is stated as SIL3 according to IEC 61508 and SILCL3 according to EN 62061.

What is the operating temperature range?

The operating temperature range is -10 °C to +70 °C.

What enclosure protection rating is stated?

The datasheet states IP67 according to EN 60529.