Danfoss Heating RET1000 Installation Instructions
Installation guide for the Danfoss RET1000B, RET1000M and RET1000MS electronic dial setting thermostats. It provides specifications, mounting requirements, wiring diagrams for each model, DIL switch settings for on/off and chrono-proportional control, and temperature limiting.
Mounting instructions call for installation by a qualified electrician or competent heating installer at about 1.5 m from the floor and away from draughts or heat sources. The document also explains DIL switch cycle choices for radiator systems and underfloor heating and lists electrical and environmental ratings.
| Operating voltage (mains) | 230 Vac ±15%, 50/60 Hz |
|---|---|
| Battery supply | 2.5-3 VDC (2xAA batteries) |
| Output | 230 Vac volt free |
| Setting temperature range | 5-30°C |
| Operating temperature range | 0-45°C |
| Switch rating | 3 A (1) at 230 Vac |
| Switch type | 1 x SPDT Type 1B |
| IP rating | IP20 |
| Dimensions | H84 x W84 x D37 mm |
| Construction | EN 60730-2-9 |
| Rated impulse voltage | 2.5 kV |
The setting temperature range is 5-30°C.
Mount it at about 1.5 m from the floor.
It should be installed only by a qualified electrician or competent heating installer.
The CHRONO setting is an energy-saving feature that fires the boiler at regular intervals to maintain a set temperature.