Danfoss APT DN 15-50 Operating Guide

This manual introduces the Danfoss APT DN 15-50 product features, including installation methods, operating instructions, etc.


Danfoss APT DN 15-50 Operating Guide - cover page
Brand
Danfoss
Category
Other products
Document type
User Manual
Language
English
Pages
2
File format
PDF
File size
1.6 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
DC1F986B73EBE66D4151C31AE6F0E76F

About this manual

This Danfoss APT DN 15-50 operating guide covers installation dimensions, pressure and temperature limits, and basic shut-off, setting, and flushing operations. It includes nominal size and thread information for DN 15 through DN 50.

What's inside

  • Installation
  • Shut off
  • Setting
  • Flushing
  • Close/Open

Specifications

Nominal diameter rangeDN 15-50
Maximum differential pressure150 kPa
Pressure ratingPN 16
Thread standardsInternal ISO 7/1, external ISO 228/1

Frequently asked questions

What is the maximum differential pressure for the APT DN 15-50?

The maximum differential pressure is 150 kPa.

What pressure rating is specified?

The pressure rating is PN 16.

Which nominal sizes are covered?

The covered nominal sizes are DN 15 to DN 50.