Figaro CMM5042 Carbon Monoxide Sensor Module Datasheet

CMM5042 is an embedded CO sensor module with high linear output characteristics, wide driving voltage range, internal temperature compensation circuit and self-diagnostic control signal input port.


Figaro CMM5042 Carbon Monoxide Sensor Module Datasheet - cover page
Brand
Figaro
Category
sensor
Document type
Datasheet
Language
Chinese
Pages
2
File format
PDF
File size
534 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
9FFF0D434800F0464940105EDFA21A16

About this manual

The Figaro CMM5042 is an embedded carbon monoxide sensor module built around the electrochemical TGS5042 sensor. It is intended for home and commercial CO alarms, automatic ventilation-fan control, and CO monitoring of gas boilers and oil/LPG heaters.

The module gives a linear analog voltage output proportional to CO concentration and includes built-in temperature compensation plus a TEST-pin self-diagnosis input. It measures 56 x 29 x 22 mm and weighs about 19 g. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Features
  • Applications
  • Pin Settings
  • Output Characteristics
  • Specifications
  • Structure and Dimensions
  • Self-Diagnosis

Specifications

SensorTGS5042 (electrochemical sensor)
Detection range0 ~ 800 ppm CO
Input voltage2.5 ~ 5.3 V DC
Signal output0 ~ 2 V DC
Warm-up time<= 30 s
Operating humidity5 ~ 95 %RH
Response time (T90)<= 60 s
Dimensions56 x 29 x 22 mm
Weightabout 19 g

Frequently asked questions

Which sensor is built into the CMM5042 module?

It uses the Figaro TGS5042 electrochemical sensor.

What is the CO detection range?

The detection range is 0 to 800 ppm CO.

How is self-diagnosis performed?

Connect the TEST pin to GND for 5 seconds, then release; normal operation is indicated when the output exceeds 3.0 V and then drops to 1.5 V.