Figaro TGS813 Combustible Gas Sensor Datasheet

This datasheet details the Figaro TGS813 semiconductor gas sensor, designed for detecting combustible gases like methane and propane with high sensitivity.


Figaro TGS813 Combustible Gas Sensor Datasheet - cover page
Brand
Figaro
Category
Other Electronics
Document type
Datasheet
Language
Chinese
Pages
13
File format
PDF
File size
1005 KB
Published
18 October, 2026
Updated
18 October, 2026
MD5 checksum
C6D121853D517746B9A07B6B870F17F4

About this manual

The Figaro TGS813 is a semiconductor gas sensor specifically designed for detecting combustible gases such as methane, propane, and butane. It features high sensitivity to these gases, making it suitable for applications in home gas leak alarms and industrial combustible gas detectors. The sensor utilizes a tin dioxide (SnO2) sensing element that changes conductivity based on the concentration of target gases. This manual is written in Chinese.

What's inside

  • TGS Sensor Product Introduction
  • Basic Test Circuit
  • Specifications
  • Structure and Dimensions
  • Electrical Characteristics
  • Pin Connection

Specifications

Element Type8 Series
Target GasCombustible gas
Detection Range500~10,000 ppm
Heater Voltage (VH)5.0±0.2V DC/AC
Circuit Voltage (VC) Max24V
Sensor Resistance (Methane 1000ppm)5~15KΩ
Sensitivity (CH4:3000ppm)0.6±0.05Rs
Preheat Time7 days or more

Frequently asked questions

What gases is the TGS813 sensor sensitive to?

The sensor has high sensitivity to methane, propane, and butane.

What is the detection range for combustible gases?

The detection range is from 500 to 10,000 ppm.

What voltage is required for the heater?

The heater requires a DC or AC voltage of 5.0±0.2V.