NGM2611 - E13 is a methane pre-calibration module with an anti-interference sensor TGS2611. It features factory calibration and temperature compensation circuit. It is compact in size and compliant with ROHS requirements. It is suitable for controlling residential gas alarms.
The Figaro NGM2611-E13 is a pre-calibration module designed for civil natural gas alarmers. It features a factory-calibrated sensor (TGS2611-E00) with an interference filter to eliminate alcohol, offering high selectivity and fast response to methane. The module includes a built-in temperature compensation circuit and a small power methane gas sensor combined with a thermistor. This manual is written in Chinese.
| Sensor Model | TGS2611-E00 |
|---|---|
| Operating Temperature | 0°C~40°C |
| Heater Voltage | 5.0±0.2V DC |
| Heater Current | 56±5mA |
| Circuit Current | 10mA (max) |
| Reference Voltage Range | 1.0~4.0V DC |
| Output Voltage Range | 0.05 -(VC-0.05)V DC |
| Operating Humidity | 30~95%RH |
It is a pre-calibration module for civil natural gas alarmers that simplifies the calibration process and reduces costs.
The recommended operating heater voltage is 5.0±0.2V DC.
It can be used for LP gas detectors, but Figaro advises consulting them before applying it to LP gas alarmers outside of civil use.