Figaro NGM2611-E13 Methane Pre-calibration Module Product Leaflet

NGM2611 - E13 is a methane pre-calibration module with an anti-interference sensor TGS2611. It features factory calibration and temperature compensation circuit. It is compact in size and compliant with ROHS requirements. It is suitable for controlling residential gas alarms.


Figaro NGM2611-E13 Methane Pre-calibration Module Product Leaflet - cover page
Brand
Figaro
Category
Other Electronics
Document type
Product Leaflet
Language
Chinese
Pages
3
File format
PDF
File size
447 KB
Published
08 January, 2023
Updated
28 September, 2023
MD5 checksum
A3BCE649EF374672B3A768FE7183D6D5

About this manual

The Figaro NGM2611-E13 is a pre-calibration module designed for civil natural gas alarmers. It features a factory-calibrated sensor (TGS2611-E00) with an interference filter to eliminate alcohol, offering high selectivity and fast response to methane. The module includes a built-in temperature compensation circuit and a small power methane gas sensor combined with a thermistor. This manual is written in Chinese.

What's inside

  • 产品介绍
  • 规格
  • 结构以及尺寸
  • 性能保证
  • 基本测试电路
  • 绝对最大额定值
  • 注意
  • 部件明细

Specifications

Sensor ModelTGS2611-E00
Operating Temperature0°C~40°C
Heater Voltage5.0±0.2V DC
Heater Current56±5mA
Circuit Current10mA (max)
Reference Voltage Range1.0~4.0V DC
Output Voltage Range0.05 -(VC-0.05)V DC
Operating Humidity30~95%RH

Frequently asked questions

What is the purpose of the NGM2611-E13 module?

It is a pre-calibration module for civil natural gas alarmers that simplifies the calibration process and reduces costs.

What is the recommended heater voltage?

The recommended operating heater voltage is 5.0±0.2V DC.

Can this module be used for LP gas detectors?

It can be used for LP gas detectors, but Figaro advises consulting them before applying it to LP gas alarmers outside of civil use.