Busch Seco SV/SD/DC Dry Rotary Vane Vacuum Pump User Manual

This manual describes the use, maintenance and maintenance of BUSCH Secro dry rotary vane vacuum pumps, including safety, product description, transportation, storage, installation, electrical connection, initial operation, maintenance, overhaul, scrapping, repair parts and other contents.


Busch Seco SV/SD/DC Dry Rotary Vane Vacuum Pump User Manual - cover page
Brand
Busch
Category
Other products
Document type
User Manual
Language
Spanish
Pages
24
File format
PDF
File size
6.1 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
DD62F5AED4F064B01515C93CB74F1C1E

About this manual

This manual covers Busch Seco dry rotary vane vacuum pumps and compressors in the SV, SD and DC series. It describes safety, transport, storage, installation, initial startup, maintenance, troubleshooting and technical data.

The machines operate without lubrication in the compression chamber and are intended for dry, non-aggressive, non-toxic and non-explosive gases. Available series and accessories vary by vacuum, pressure or combined vacuum and pressure duty. This manual is written in Spanish.

What's inside

  • Safety
  • Product description
  • Transport
  • Storage
  • Installation
  • Initial startup
  • Maintenance
  • Troubleshooting
  • Technical data
  • EU declaration of conformity

Specifications

Suction connection size (SV/SD 1010-1016 C)G1/2
Suction connection size (SV/SD 1025-1040 C and DC 0025-0040 C)G3/4
Exhaust connection size (SD 1010-1016 C)G1/2
Exhaust connection size (SD 1025-1040 C and DC 0025-0040 C)G3/4
Exhaust connection (SV 1010-1040 C)No dimensions; exhaust valve (DV)
Storage temperature0 to 40 C
Altitude requiring Busch consultationAbove 1000 m above sea level
Inlet filter for dusty gas5 microns or less
OperationContinuous operation possible

Frequently asked questions

What gases can the pump be used with?

It is designed for suction of dry air and other dry gases that are not aggressive, toxic or explosive.

Can the compression chamber be lubricated?

No. Lubricating the dry-running compression chamber with oil or grease can damage the machine.

What storage temperature is recommended?

Store the machine in a closed, dry, dust-free place at 0 to 40 C.

What inlet filtration is needed for dusty gas?

Install a suitable filter of 5 microns or less upstream of the machine.

Download PDF (6.1 MB)