Busch PANDA WV 1200 A, WV 1800 A, WV 2400 A Vacuum Booster Instruction Manual

This document introduces the instructions for use of the PANDA Vacuum Booster WV 1200 A, WV 1800 A, WV 2400 A, including safety, product description, transportation, storage, installation, connection, electrical connection, commissioning, maintenance, overhaul, decommissioning, spare parts, troubleshooting, technical data, maximum permissible differential pressure, oil, etc.


Busch PANDA WV 1200 A, WV 1800 A, WV 2400 A Vacuum Booster Instruction Manual - cover page
Brand
Busch
Category
Other
Document type
User Manual
Language
English
Pages
36
File format
PDF
File size
9.4 MB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
DA4D1CA054B099631EFF018D66E0C531

About this manual

The Busch PANDA WV 1200 A, WV 1800 A and WV 2400 A are vacuum boosters intended for industrial use. This instruction manual covers safety, product description, transport, storage, installation and electrical connection.

It also covers commissioning, maintenance, overhaul, decommissioning, spare parts, troubleshooting, technical data, maximum permissible differential pressures, oil, and EU/UK declarations of conformity.

What's inside

  • Safety
  • Product Description
  • Transport
  • Storage
  • Installation
  • Electrical Connection
  • Commissioning
  • Maintenance
  • Troubleshooting
  • Technical Data

Specifications

Nominal pumping speed (WV 1200 A, 50 Hz / 60 Hz)1050 / 1260 m³/h
Nominal motor rating (WV 1200 A, 50 Hz / 60 Hz)3.5 / 4.8 kW
Sound pressure level (WV 1200 A, 50 Hz / 60 Hz)59 / 63 dB(A)
Ambient temperature range5 … 40 °C
Maximum gas inlet temperature200 °C (P <10 hPa, staging ratio of 4)
Oil capacity, WV 1200 A (motor side)1.6 l
Weight (approx.)290 kg (WV 1200 A), 300 kg (WV 1800 A), 520 kg (WV 2400 A)
Suction connection sizeDN160, DIN 28404

Frequently asked questions

What gases can the vacuum booster handle?

The machine is intended for the suction of air and other dry, non-aggressive, non-toxic and non-explosive gases.

What is the permitted ambient temperature range?

The permitted ambient temperature range is 5 to 40 °C.

Which oil types are listed for the vacuum booster?

The manual lists VSC 100 and VSL 100, both ISO-VG 100.

What suction connection size is specified?

The listed suction connection size is DN160, DIN 28404.