This document introduces the instructions for use of the PANDA Vacuum Booster WV 1200 A, WV 1800 A, WV 2400 A, including safety, product description, transportation, storage, installation, connection, electrical connection, commissioning, maintenance, overhaul, decommissioning, spare parts, troubleshooting, technical data, maximum permissible differential pressure, oil, etc.
The Busch PANDA WV 1200 A, WV 1800 A and WV 2400 A are vacuum boosters intended for industrial use. This instruction manual covers safety, product description, transport, storage, installation and electrical connection.
It also covers commissioning, maintenance, overhaul, decommissioning, spare parts, troubleshooting, technical data, maximum permissible differential pressures, oil, and EU/UK declarations of conformity.
| Nominal pumping speed (WV 1200 A, 50 Hz / 60 Hz) | 1050 / 1260 m³/h |
|---|---|
| Nominal motor rating (WV 1200 A, 50 Hz / 60 Hz) | 3.5 / 4.8 kW |
| Sound pressure level (WV 1200 A, 50 Hz / 60 Hz) | 59 / 63 dB(A) |
| Ambient temperature range | 5 … 40 °C |
| Maximum gas inlet temperature | 200 °C (P <10 hPa, staging ratio of 4) |
| Oil capacity, WV 1200 A (motor side) | 1.6 l |
| Weight (approx.) | 290 kg (WV 1200 A), 300 kg (WV 1800 A), 520 kg (WV 2400 A) |
| Suction connection size | DN160, DIN 28404 |
The machine is intended for the suction of air and other dry, non-aggressive, non-toxic and non-explosive gases.
The permitted ambient temperature range is 5 to 40 °C.
The manual lists VSC 100 and VSL 100, both ISO-VG 100.
The listed suction connection size is DN160, DIN 28404.