This is the instruction manual for the PANDA WV 0250 C, WV 0500 C products. This manual covers the safety, transportation, storage, installation, electrical connection, commissioning, maintenance, overhaul, decommissioning and other content of the product.
The Busch PANDA WV 0250 C and WV 0500 C are vacuum boosters that work on the booster blower principle. The two oil housings lubricate the gears, bearings and, in certain versions, oil-lubricated mechanical seals; a bypass valve limits the differential pressure between inlet and outlet. The machine is intended for continuous operation in a non-potentially explosive environment, used in combination with a backing pump to draw air and other dry, non-aggressive, non-toxic and non-explosive gases.
This instruction manual covers safety, product description, transport, storage, installation, electrical connection, commissioning, maintenance, overhaul, decommissioning, spare parts, troubleshooting, technical data, oil and declarations of conformity. It is written for technically trained personnel handling the machine for industrial use.
| Nominal pumping speed (50Hz / 60Hz) | WV 0250 C: 250 / 300 m³/h; WV 0500 C: 500 / 600 m³/h |
|---|---|
| Nominal motor rating (50Hz / 60Hz) | WV 0250 C: 1.1 / 1.2 kW; WV 0500 C: 2.2 / 3.0 kW |
| Nominal motor speed (50Hz / 60Hz) | WV 0250 C: 1500 / 1800 min-1; WV 0500 C: 3000 / 3600 min-1 |
| Ambient temperature range | 5 … 40 °C |
| Max. gas inlet temperature | 200 °C (P <10 hPa, staging ratio of 4) |
| Oil capacity (motor side) | 0.4 l for WV 0250 C and WV 0500 C |
| Oil capacity (gear side) | 0.5 l for WV 0250 C and WV 0500 C |
| Oil capacity (oiler) | 0.35 l for WV 0250 C and WV 0500 C |
| Weight approx. | 146 kg |
It is intended for the suction of air and other dry, non-aggressive, non-toxic and non-explosive gases.
Yes, the machine is suitable for continuous operation.
The maximum gas inlet temperature is 200 °C at P <10 hPa with a staging ratio of 4.
The motor-side oil capacity is 0.4 l for both WV 0250 C and WV 0500 C.