About this manual

This manual covers the installation, commissioning, maintenance, and overhaul of Busch vacuum boosters operating on the Roots blower principle. It provides detailed instructions for electrical connections, oil filling, and safety precautions for industrial use.

What's inside

  • Safety
  • Product Description
  • Installation
  • Commissioning
  • Maintenance
  • Overhaul
  • Decommissioning
  • Spare Parts
  • Troubleshooting
  • Technical Data

Specifications

Nominal pumping speed (50Hz)250, 500, 1000, 1500, 2000 m³/h
Nominal motor rating (50Hz)1.1, 2.2, 3.5, 4.2, 6.0 kW
Ambient temperature range5 ... 40 °C
Max. gas inlet temperature200 °C
Oil typeVE 101 VSL 100 ISO-VG 100

Frequently asked questions

What is the operating principle of the machine?

The machine works on the Roots blower principle.

What gases is the machine intended for?

The machine is intended for the suction of air and other dry, non-aggressive, non-toxic and non-explosive gases.

What oil should be used?

Only use an oil type which has previously been approved and recommended by Busch.

What is the maximum ambient temperature?

The maximum ambient temperature is 40 °C.