SSW-07/SSW-08 Soft Starter DeviceNet Communication Manual

This document is the DeviceNet communication manual for SSW-07/SSW-08 starter


SSW-07/SSW-08 Soft Starter DeviceNet Communication Manual - cover page
Category
motor starter
Document type
User Manual
Language
Spanish
Pages
21
File format
PDF
File size
586 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
A030D6666866B9BA873C106523FF5EE4

About this manual

This is the DeviceNet Communication Manual (Manual de Comunicación DeviceNet, document 10000046974/00, dated 03/2008) for the SSW-07/SSW-08 soft starter (Arrancador Suave). It is written in Spanish and describes how to operate the SSW-07/SSW-08 on a DeviceNet network using the KFB-DN accessory kit. The manual states it must be used together with the SSW-07/SSW-08 user manual.

The content includes an introduction to CAN and DeviceNet (frames, network access, error control, physical layer, CIP protocol and master/slave connection set), installation and configuration of the CAN interface kit, parameterization of the soft starter (P090–P347, including CAN address, baud rate, I/O instances and read/write parameters), and the communication-related errors E33, E34, E36 and E37.

What's inside

  • Sobre el Manual
  • Introducción a la Comunicación DeviceNet
  • CAN
  • DeviceNet
  • Kit Accesorio (KFB-DN)
  • Conexión con la Red
  • Configuración del Módulo
  • Parametrización del Arrancador Suave
  • Errores Relacionados con la Comunicación DeviceNet

Specifications

DeviceNet network power supply24 Vdc, DC output isolated from AC input
Network trunk length at 125 kbps500 m (max. drop 156 m)
Network trunk length at 500 kbps100 m (max. drop 6 m / 39 m)
Termination resistors121 Ω, 0.25 W, 1% tolerance, at both ends of the network
Maximum devices per DeviceNet network64 (addresses 0–63)
CAN connector5-way plug-in connector

Frequently asked questions

What does error E33 on the SSW-07/SSW-08 mean?

E33 indicates that there is no power supply on the CAN interface.

How many devices can be connected to a DeviceNet network?

A DeviceNet network can contain up to 64 devices, addressed from 0 to 63; address 63 is usually reserved for commissioning purposes.

Can this DeviceNet manual be used on its own?

No, the manual states it must be used together with the SSW-07/SSW-08 user manual.

What does error E37 indicate?

E37 is a timeout in the DeviceNet connection.

Download PDF (586 KB)