Eaton DE1 Variable Speed Starter Reversing Motor Starting Application Note

Eaton application note AP040 101EN on configuring the DE1 Variable Speed Starter for reversing motor starting using the DXE-EXT-SET module.


Eaton DE1 Variable Speed Starter Reversing Motor Starting Application Note - cover page
Brand
Eaton
Category
motor starter
Document type
Application Note
Language
English
Pages
5
File format
PDF
File size
105 KB
Published
06 November, 2026
Updated
06 November, 2026
Model
DE1
MD5 checksum
158D69F68A86EEA7FA662AC42A2295FE

About this manual

This Eaton application note (AP040 101EN, effective February 2015) explains how to configure the DE1 Variable Speed Starter for reversing motor starting applications. The DE1 combines the ease of use of a direct online (DOL) starter with the variable motor speed of a variable frequency drive, giving a soft motor start with full torque at low motor RPM while avoiding inrush current peaks.

The document describes setup with the DXE-EXT-SET configuration module, which snaps onto the face of the DE1 and is used to set ramp times, fixed frequency, mode selection, motor FLA and supply frequency. It also covers transferring parameter values from the module to the DE1, the Mode 0 terminal assignments, and a connection diagram for a reversing starter application.

What's inside

  • DXE-EXT-SET Configuration Module Functionality
  • Parameterization with the DXE-EXT-SET Configuration Module
  • Supply Voltage Parameterization
  • Transfer parameter values of the DXE-EXT-SET module to the DE1
  • DE1 Functionality – Mode 0 Terminal Assignment
  • DE1 Functionality – Connection Diagram for a reversing starter application
  • Additional Help

Specifications

Ramp time parameter (P-03)0.1-300 sec, default 5
Stop ramp parameter (P-04)0.1-300 sec
Mode parameter (P-15)0-9, default 0
Fixed frequency parameter (P-20)0-60 Hz, default 20
Motor FLA (protection) parameter (P-08)10%-100% x Ie, default 100%
Supply frequency parameter (P-09)50-60 Hz, default 60
Supply voltage 200-240 Vac range200-240 Vac ± 10%, P-07 = 230
Supply voltage 400-480 Vac range400-480 Vac ± 10%, P-07 = 460
Terminal assignment profilesTen (10)

Frequently asked questions

How do I transfer parameter values from the DXE-EXT-SET module to the DE1?

Put the DE1 in STOP mode with supply voltage applied and press the SET button for 2 seconds. The status LED flashes green 3 times, and a steady green LED indicates all parameters were transferred successfully.

Can the DXE-EXT-SET module upload parameters from the DE1?

No. The module can only download the potentiometer values from the module into the DE1; it cannot upload parameters from a DE1 into the module.

What ramp time is used when digital input 1 receives a signal?

The DE1 accelerates the motor in the forward direction with a ramp of 5 seconds (the default value) to motor synchronous speed, and decelerates with a 5 second ramp (12Hz/second) when the signal is removed.

Which terminal provides the frequency set point reference in Mode 0?

Terminal 4 / digital/analog input 4 (f-REF) is connected to Terminal +10V to provide a reference signal to command the motor to synchronous speed.