YX8000 Series High-Performance Universal Vector Inverter User Manual

YX8000 series high performance universal vector inverter user manual, introduces the inverter overview, product introduction, installation and connection, parameter setting, operation and maintenance


YX8000 Series High-Performance Universal Vector Inverter User Manual - cover page
Category
inverter
Document type
User Manual
Language
Chinese
Pages
137
File format
PDF
File size
3.5 MB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
C094DE7B2D83FF06B06887FDCB2B87B1

About this manual

The YX8000 Series is described as a high-performance current-vector, low-noise inverter developed by the manufacturer. The manual states that it adds simple PLC, PID regulation with constant-pressure water supply, flexible input/output terminals, online parameter changes, signal-transmission fault self-detection, parameter storage after power loss or stop, injection molding machine energy-saving control, swing-frequency control, RS485 control, PG encoder closed-loop control, and fieldbus control.

The manual covers product confirmation and safety, model and technical specifications, installation dimensions and braking resistor, installation and wiring, operation panel use and quick commissioning, function parameter tables and detailed parameter groups P0 through PE, fault diagnosis, maintenance, and the RS485 communication protocol. This manual is written in Chinese.

What's inside

  • Product confirmation and safety precautions
  • Inverter series models and technical specifications
  • Installation dimensions and braking resistor
  • Installation direction, space and peripheral equipment connection
  • Wiring terminals and standard wiring diagram
  • Operation panel use and quick commissioning
  • Function parameter table
  • Detailed function code groups P0-PE
  • Fault diagnosis and maintenance
  • RS485 communication protocol

Specifications

Voltage grades in model code220 V (code 2); 380 V (code 4)
Input phase optionsSingle-phase (code S); three-phase (code T)
Inverter type codeG = constant torque; P = fan/pump type
Motor power code examples0007 = 0.75 kW; 0015 = 1.5 kW; 0075 = 7.5 kW

Frequently asked questions

What do the G and P codes in the YX8000 model mean?

G denotes constant torque and P denotes the fan/pump type.

Which voltage grades are shown in the YX8000 model code?

The code uses 220 V (code 2) and 380 V (code 4) voltage grades.

What must be confirmed before wiring the inverter?

The input power must be switched off before wiring.

What communication protocol does the manual cover?

It covers the RS485 serial communication protocol.

Download PDF (3.5 MB)

Also Manuals