Mitsubishi Electric E800 is a new inverter with high performance, ease of use, flexibility and high safety. It supports CC-Link IE TSN, EtherNet/IP, PROFINET, EtherCAT and other industrial network protocols, and can be widely used in industrial automation.
The FREQROL-E 800 is a Mitsubishi Electric general-purpose inverter presented in this Chinese-language catalog. The catalog identifies standard model E800, Ethernet model E800-E, and safety communication model E800-SCE, and it describes CC-Link IE TSN, multiprotocol Ethernet, environment diagnostics, AI alarm diagnosis, and safety functions.
The table of contents lists features, operation panel and operating procedure, parameter list, protective functions, standard specifications, outline dimensions, terminal connection diagrams, connection examples, options, and selection precautions. Feature pages also cite capacity expansion to 18.5K and 22K, a 575 V class, an ambient temperature range of -20°C to 60°C, IEC60721-3-3 (3C2) corrosive-gas compliance, and IP67 models (FR-E846). This manual is written in Chinese.
| Series / model | FREQROL-E 800 |
|---|---|
| Expanded capacities | 18.5K and 22K |
| Expanded voltage class | 575 V |
| Ambient temperature | -20°C to 60°C |
| Derating | Above 50°C |
| Corrosive gas class | IEC60721-3-3 (3C2) |
| Protection rating | IP67 (FR-E846) |
| Standard network | CC-Link IE TSN |
| Ethernet ports | 2 |
| Supported industrial Ethernet protocols | EtherNet/IP, PROFINET, EtherCAT, etc. |
| Functional safety standards | IEC61508, SIL3, etc. |
CC-Link IE TSN is standard.
Yes. The catalog describes multiprotocol support and lists EtherNet/IP, PROFINET, and EtherCAT.
The catalog lists -20°C to 60°C.
The catalog cites IEC61508 and SIL3 functional safety standards.