67D series pressure regulators, made of aluminum or stainless steel, with or without internal relief valves. Maximum inlet pressure is 27.6 bar / 400 psig and maximum outlet pressure is 17.2 bar / 250 psi.
This manual provides installation, maintenance, and parts ordering information for Fisher 67D series direct-acting pressure regulators, which are used to provide continuous controlled reduced pressure for most air or gas applications. It covers available configurations, technical specifications, body sizes and connections, outlet pressure ranges, flow coefficients, temperature and filter performance, and optional features.
It also explains the operating principle, internal relief valve operation, Smart Bleed option, installation guidelines and warnings, and includes Table 1 with outlet pressure ranges and control spring data. This manual is written in Chinese.
| Body size and inlet/outlet connections | 1/2 NPT |
|---|---|
| Maximum inlet pressure, filtered models | 17.2 bar / 250 psig |
| Maximum inlet pressure, unfiltered models | 27.6 bar / 400 psig |
| Outlet pressure range | See Table 1 |
| Maximum emergency outlet pressure | 10.3 bar / 150 psi above setting, not exceeding 17.2 bar / 250 psi |
| Full-open flow coefficient, main valve | Cg 45.24; Cv 1.33; C1 35.02 |
| Full-open flow coefficient, internal relief valve | Cg 1.45; Cv 0.045; C1 32.8 |
| IEC sizing coefficient | Xt 0.75 |
| Approximate weight | 0.5 kg (67D/67DR), 1 kg (67DF/67DFR), 1 kg (67DS/67DSR), 2 kg (67DFS/67DFSR) |
| Smart Bleed check valve set point | 0.41 bar / 6 psi differential |
| Operating temperature, NBR with standard bolts | -29 to 82 C (-20 to 180 F) |
| Filter rating, standard polyethylene filter | 5 microns |
| Spring box vent position | Standard aligned with inlet; other positions available |
| Drain valve position | Centered in drip well |
| Pressure tap | Internal |
67DF, 67DFR, 67DFS, and 67DFSR include a filter for removing particles from the supply gas.
67DR, 67DSR, 67DFR, and 67DFSR include an internal relief valve and soft seat for reliable shutoff.
Filtered models are rated to 17.2 bar / 250 psig, and unfiltered models are rated to 27.6 bar / 400 psig.
The main valve is Cg 45.24, Cv 1.33, C1 35.02; the internal relief valve is Cg 1.45, Cv 0.045, C1 32.8.