Instructions for connecting devices and PLCs
This appendix belongs to the GP-PRO/PBIII for Windows Device/PLC Connection Manual. It lists, for each supported controller, the maximum number of consecutive device addresses that can be read, covering PLC series such as MICREX-F, MICREX-SX, FLEX-PC and FLEX-PC N, the Micro-Controller X Series (Model: PXR), and inverter series FRENICS5000G11S, FRENICS5000P11S, FVR-E11S and FVR-C11S.
The appendix also gives device codes and address codes used to specify indirect addresses for E-tags and K-tags, with word address tables for bit devices and word devices, including LS areas. Notes explain that data communication speed declines when consecutive addresses exceed the maximum range, when an address is designated for division, or when device types are different, and recommend planning the tag layout in screen units as consecutive devices.
| MICREX-SX Series maximum number of consecutive addresses | 243 words |
|---|---|
| Inverter (FRENICS5000G11S, FRENICS5000P11S, FVR-E11S, FVR-C11S) maximum consecutive addresses for option/instruction/monitor data | 1 word |
| FLEX-PC N Series maximum number of consecutive addresses | 105 words |
The data communication speed declines by the number of times the device is read.
Plan the tag layout in screen units as consecutive devices, including the Alarm and Trend screens.
They are used to specify indirect addresses for the E-tags or K-tags.
When consecutive addresses exceed the maximum data number range, when an address is designated for division, or when device types are different.