Fuji Electric GP-PRO/PBIII for Windows Device/PLC Connection Manual Appendix

Instructions for connecting devices and PLCs


Fuji Electric GP-PRO/PBIII for Windows Device/PLC Connection Manual Appendix - cover page
Brand
Fuji Electric
Category
Programming
Document type
Programming Manual
Language
English
Pages
7
File format
PDF
File size
129 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
CA03CA66AB50CD4F6C5400683AB5D9F0

About this manual

This appendix belongs to the GP-PRO/PBIII for Windows Device/PLC Connection Manual. It lists, for each supported controller, the maximum number of consecutive device addresses that can be read, covering PLC series such as MICREX-F, MICREX-SX, FLEX-PC and FLEX-PC N, the Micro-Controller X Series (Model: PXR), and inverter series FRENICS5000G11S, FRENICS5000P11S, FVR-E11S and FVR-C11S.

The appendix also gives device codes and address codes used to specify indirect addresses for E-tags and K-tags, with word address tables for bit devices and word devices, including LS areas. Notes explain that data communication speed declines when consecutive addresses exceed the maximum range, when an address is designated for division, or when device types are different, and recommend planning the tag layout in screen units as consecutive devices.

What's inside

  • About the Device/PLC Connection Manuals
  • Maximum Number of Consecutive Device Addresses
  • Device Codes and Address Codes
  • MICREX-F Series
  • FLEX-PC N Series
  • MICREX-SX Series
  • Micro-Controller X Series (Model: PXR)
  • FLEX-PC Series
  • FRENICS5000G11S, FRENICS5000P11S, FVR-E11S, FVR-C11S Series
  • LS Area

Specifications

MICREX-SX Series maximum number of consecutive addresses243 words
Inverter (FRENICS5000G11S, FRENICS5000P11S, FVR-E11S, FVR-C11S) maximum consecutive addresses for option/instruction/monitor data1 word
FLEX-PC N Series maximum number of consecutive addresses105 words

Frequently asked questions

What happens to communication speed when consecutive addresses exceed the maximum data number range?

The data communication speed declines by the number of times the device is read.

How can data communication be speeded up?

Plan the tag layout in screen units as consecutive devices, including the Alarm and Trend screens.

What are device codes and address codes used for?

They are used to specify indirect addresses for the E-tags or K-tags.

Which address designations cause the communication speed to decline?

When consecutive addresses exceed the maximum data number range, when an address is designated for division, or when device types are different.