This manual mainly introduces the basic functions, operating methods, calibration methods, and usage precautions of the TUD5100 digital ultrasonic flaw detector.
This manual covers a portable, all-digital ultrasonic flaw detector used for fast, non-destructive detection, location and evaluation of internal defects such as welds, cracks, inclusions and porosity, both in the laboratory and at a work site. It presents the safety notes, functional features, technical specifications, main unit layout, display interfaces, keypad, menu structure, indicators and charging instructions.
The rest of the document explains basic operation, calibration of straight, angle and dual-crystal probes, creation and adjustment of DAC and AVG curves, and auxiliary inspection functions such as crack depth measurement, video recording, peak memory, echo envelope, B-scan, AWS and curved-surface correction. It closes with factors affecting detection accuracy, defect evaluation methods, maintenance and troubleshooting, plus an appendix of terms and related standards. This manual is written in Chinese.
| Detection range | 0 to 9999 mm |
|---|---|
| Sound velocity range | 1000 to 9999 m/s |
| Gain range | 0 to 110 dB |
| Probe zero offset | 0 to 1000 µs |
| Operating frequency | 0.2 to 15 MHz |
| Electrical noise level | ≤10% |
| Sensitivity margin | >62 dB |
| Resolution | >40 dB |
| Vertical linearity error | ≤3% |
| Horizontal linearity error | ≤0.1% |
| Dynamic range | ≥32 dB |
| Pulse strength | 5 adjustable levels (100 V, 250 V, 400 V, 500 V) |
| Repeat frequency | Auto low, auto medium, auto high, 5 to 1000 Hz |
| Ambient temperature | -10 °C to +50 °C |
| Ambient humidity | 20% to 95% |
The detection range is 0 to 9999 mm.
No. The manual states it is industrial ultrasonic non-destructive testing equipment and must not be used for medical testing.
It can store 100 inspection channels and 1000 waveforms, with video recording of up to 60 minutes.
Personnel who have professional non-destructive testing knowledge, to ensure safe operation.