The YTC401 is a portable single-phase relay protection tester developed by Hubei Yitiancheng Electric Power Equipment Co., Ltd. It weighs 18 kg, features a stainless steel or plastic-aluminum case, dual carbon-brush voltage regulators for simultaneous main and auxiliary circuit output, 0.5-class digital meters, and a six-digit timer for time measurements.
The device accepts AC 220 V ±10% 50 Hz input and provides multiple AC/DC voltage and current outputs up to 250 V/3 A, 100 A/15 V, and 350 V DC. It measures voltage up to 500 V, current up to 10 A, and time up to 999.999 s with 1 ms resolution. The manual includes operating procedures for relay pickup, timing, and intermediate relay tests, plus safety precautions and a three-year warranty. This manual is written in Chinese.
| Input Power | AC220V±10% 50Hz |
|---|---|
| Nominal Capacity | 1KVA |
| Main Circuit AC Voltage Output | 0-250V (3A) |
| Main Circuit AC Current Output 500mA | 0-500mA (20V) series resistor |
| Main Circuit AC Current Output 10A | 0-10A (20V) series resistor |
| Main Circuit AC Current Output 100A | 0-100A (15V) |
| Main Circuit DC Voltage Output | 0-350V (3A) |
| Main Circuit DC Current Output 10A | 0-10A (20V) |
| Main Circuit DC Current Output 500mA | 0-500mA (15V) series resistor |
| Auxiliary Circuit AC Voltage Output | 0-250V (1A), 0-20V (1A) |
| Auxiliary Circuit DC Voltage Output | 0-350V (1A) |
| Voltage Measurement Range | 0-500.0V direct |
| AC Current Measurement Range | 0-500mA direct, 0-10.00A via shunt |
| Time Measurement Range | 0-999.999s, 1ms resolution |
| Measurement Accuracy | 0.5 class |
| Dimensions | 272mm × 172mm × 262mm |
| Weight | 18 kg |
| Operating Temperature | -20°C to 45°C |
| Warranty | 3 years free repair |
The YTC401 requires AC 220 V ±10% at 50 Hz.
Connect the relay coil to the voltage output, press the output control switch, slowly increase voltage until pickup, record voltage, then decrease until release, and record release voltage.