SICK STR1-SASM0AC8 Non-contact Safety Switch Datasheet

STR1-SASM0AC8 Non-contact safety switch with 2 safety output, 1 auxiliary contact (AUX) and M12 connection, the sensor principle is frequency type.


SICK STR1-SASM0AC8 Non-contact Safety Switch Datasheet - cover page
Brand
SICK
Category
sensor
Document type
Datasheet
Language
Chinese
Pages
9
File format
PDF
File size
586 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
01054D174B026D50C104C7929B8CB958

About this manual

The SICK STR1-SASM0AC8 is a non-contact safety switch in the STR1 series. This datasheet presents its safety technology parameters, electrical and mechanical specifications, environmental ratings, dimensions and weight.

The document also includes dimensional drawings, connection and wiring diagrams, application examples, and ordering information for accessories and cables. It closes with SICK company and contact information. This manual is written in Chinese.

What's inside

  • Product features
  • Technical specifications
  • System hardware
  • Safety technology parameters
  • Electrical parameters
  • Mechanical parameters
  • Environmental parameters
  • Dimensional drawing
  • Wiring diagram
  • Accessories

Specifications

Safety integrity levelSIL3 (IEC 61508), SILCL3 (EN 62061)
Performance levelPL e (EN ISO 13849)
Mission time20 years (EN ISO 13849)
Supply voltage24 V DC (19.2 V DC to 28.8 V DC)
Current consumption50 mA
Output typeSemiconductor output (OSSD)
Dimensions40 mm x 18 mm x 26 mm
Housing materialVISTAL
Enclosure ratingIP67 (EN 60529)
High-pressure cleaning ratingIPX9K (ISO 20653)
Operating temperature-10 °C to +70 °C
Storage temperature-25 °C to +70 °C
Vibration resistance10 Hz to 55 Hz, 1 mm (IEC 60068-2-6)
Shock resistance30 g, 11 ms (IEC 60068-2-27)

Frequently asked questions

What safety integrity level does the STR1-SASM0AC8 support?

It supports SIL3 (IEC 61508) and SILCL3 (EN 62061).

What is the supply voltage of the STR1-SASM0AC8?

It uses 24 V DC, with an operating range of 19.2 V DC to 28.8 V DC.

What is the operating temperature range?

-10 °C to +70 °C.

What is the enclosure rating?

IP67 (EN 60529).