This document is the operating characteristics and handling manual for the NAP-505 Carbon Monoxide Gas Sensor
The NAP-505 is a small, electrochemical carbon monoxide gas sensor designed for use in residential and light commercial applications. It features a three-electrode system housed in a PPO enclosure with an air vent to prevent electrolyte leakage under varying temperature and humidity conditions. The sensor is designed to be soldered directly to a PCB and offers a long expected lifetime of 7 years in appropriate environments.
| Detected Gas | Carbon Monoxide |
|---|---|
| Standard concentration range | 0 - 1000ppm |
| Output Sensitivity | 40nA ± 10nA/ppm |
| Response Time (T90T) | <30 secs |
| Expected Lifetime | 7 Years |
| Operating Temperature Range | -20 to +50 degree C |
| Enclosure Material | PPO |
| Weight | 2.6g |
The expected lifetime in the field is 7 years in an appropriate residential or light commercial application.
Yes, the NAP-505 uses a unique electrode pin and socket design that allows it to be soldered directly to a PCB.
Yes, it conforms to JIA standards for use as a commercial incomplete combustion alarm and within a battery operated incomplete combustion alarm.