Nemoto NAP-505 Carbon Monoxide Gas Sensor Handling Manual

Nemoto NAP-505 Carbon Monoxide Gas Sensor Handling Manual

User Manual 30 pages · 1.8 MB · EN

The NAP-505 is a small, electrochemical carbon monoxide gas sensor designed for use in residential and light commercial applications. It features a three-electrode system housed in a PPO enclosure with an air vent to prevent electrolyte leakage under varying temperature and humidity conditions. The sensor is designed to be soldered directly to a PCB and offers a long expected lifetime of 7 years in appropriate environments.

Read online

Nemoto NAP-505 specifications

Detected GasCarbon Monoxide
Standard concentration range0 - 1000ppm
Output Sensitivity40nA ± 10nA/ppm
Response Time (T90T)<30 secs
Expected Lifetime7 Years
Operating Temperature Range-20 to +50 degree C
Enclosure MaterialPPO
Weight2.6g

Source: Nemoto NAP-505 Carbon Monoxide Gas Sensor Handling Manual

All Nemoto NAP-505 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the detection range of the NAP-505?

The sensor detects carbon monoxide in a range from 0 to 1000ppm.

From: Nemoto NAP-505 Electrochemical CO Sensor User Manual

What is the detection range for the NAP-505 sensor?

The sensor detects carbon monoxide concentrations in a range of 0 to 1000ppm.

From: Nemoto NAP-505 Electrochemical CO Sensor User Manual

What is the expected lifetime of the NAP-505 sensor?

The expected lifetime in the field is 7 years in an appropriate residential or light commercial application.

From: Nemoto NAP-505 Carbon Monoxide Gas Sensor Handling Manual

Can the NAP-505 be soldered directly to a PCB?

Yes, the NAP-505 uses a unique electrode pin and socket design that allows it to be soldered directly to a PCB.

From: Nemoto NAP-505 Carbon Monoxide Gas Sensor Handling Manual