Nemoto NAP-100AH Catalytic type gas sensor User's Manual

NAP-100AH is a hydrogen gas detector with a maximum detection concentration of 1%


Nemoto NAP-100AH Catalytic type gas sensor User's Manual - cover page
Brand
NEMOTO
Document type
User Manual
Language
English
Pages
4
File format
PDF
File size
156 KB
Published
27 October, 2023
Updated
27 October, 2023
MD5 checksum
344163B7687D02D87BE29D3A7E28A3DB

About this manual

This user manual details the NAP-100AH catalytic hydrogen gas sensor by Nemoto, designed for detecting hydrogen in concentrations up to 1% and operating up to 150°C. It is suitable for fuel battery leakage detection and industrial applications. The manual covers specifications, circuitry, calibration, and handling precautions.

The sensor features excellent selectivity, stability, and corrosion resistance, with a response time of under 20 seconds. It can be used without temperature compensation up to 150°C and is unaffected by humidity or other hydrocarbons.

What's inside

  • Applications
  • Features
  • Maximum Specifications
  • Specifications
  • Structure
  • Recommended Circuit
  • Typical Characteristics
  • Calibration of Bridge Output Voltage
  • Remarks

Specifications

Supply VoltageDC 1.6 ± 0.1V
Current130–150 mA
Operating Temperature0°C to +150°C
Operating HumidityLess than 95%RH (<100°C)
Hydrogen Sensitivity40 ± 4 mV at 5,000 ppm
Response SpeedWithin 20 seconds (90% response)
Detectable Gas Concentration Range0% to 4% (perfect linearity up to ~1.3%)
Long Term StabilityMore than 90% sensitivity after 2 years

Frequently asked questions

What is the maximum operating temperature for the NAP-100AH sensor?

The sensor can operate up to +150°C without requiring a temperature compensation circuit.

What is the response time of the sensor?

The sensor responds within 20 seconds to reach 90% of its output.

How should the sensor be calibrated?

Calibrate by mounting it on the recommended circuit, powering it for over an hour, then adjusting the zero point using V/R.

What are the storage conditions for the sensor?

Store between -20°C to +60°C and less than 99%RH (no dew condensation).