dbx ZC-4 Fire Alarm System Application Guide

ZC-4 FIRE ALARM SYSTEM APPLICATION GUIDE


dbx ZC-4 Fire Alarm System Application Guide - cover page
Brand
dbx
Category
Other Electronics
Document type
Application Note
Language
English
Pages
4
File format
PDF
File size
939 KB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
6035F30F9B0E0A48B5997157C62E3B9A

About this manual

This dbx application guide explains how to use a ZC-4 in place of a ZC-FIRE to recall a scene depending on the state of a fire alarm system. The example design uses a dbx ZonePRO 640M, though the guide notes that any ZonePRO model will suffice to an extent, with a warning that non-M models lose the ability to mute program material while keeping the announcement microphone audible.

The guide walks through the Configuration Wizard, assigning the ZC-4 to ZC Input 1, editing scene control, storing a default scene and a "Fire Scene" that mutes program audio, and finally testing scene recall with the fire alarm system wired to the ZC-4 using contact closures.

What's inside

  • Configuration Wizard
  • ZC Panel Configuration
  • Scene Control Edit
  • Storing Scene 1 as the default scene
  • Setting up the fire scene with Source Mute or Master Mute
  • Replicating mute settings for every output
  • Wiring the fire alarm system to the ZC-4 and testing scene recall

Specifications

ZonePRO connection cablestraight-thru Cat-5 cable
Control input typeContact closures (does not respond to control voltage)
Required ZC input assignmentZC Input 1

Frequently asked questions

Can a ZC-4 be used in place of a ZC-FIRE?

Yes, the guide describes using a ZC-4 in place of a ZC-FIRE to recall a scene dependent upon the state of a fire alarm system.

What cable is used between the ZonePRO and the ZC-4?

A straight-thru Cat-5 cable makes the connection between the ZonePRO and the ZC-4.

Does the ZC-4 respond to control voltage?

No, the ZC-4 will not respond to control voltage and must be used with contact closures.

Which ZC input must the ZC-4 be assigned to when used as a scene selector?

When using the ZC-4 as a scene selector, it must be assigned to ZC Input 1.