This manual describes troubleshooting methods for the MELSERVO-JE servo amplifier
This Mitsubishi Electric MELSERVO-JE servo amplifier instruction manual is for troubleshooting. It starts with safety instructions that say to read the manual before use and to keep it accessible to the operator.
The manual includes sections on servo amplifier troubleshooting, alarms, warnings, and drive recorder. It explains alarm stop methods, alarm deactivation, and corrective actions. The contents also list alarm and warning remedies and appendix detection points.
Turn SON (Servo-on) off and interrupt the power. Then refer to the troubleshooting section for the appropriate action.
After the cause of the alarm is removed, the alarm can be deactivated by alarm reset, CPU reset, or power cycling. Warnings are automatically canceled after the cause is removed.
For alarms with "SD" in the stop method column, the servo motor stops with the dynamic brake after forced stop deceleration. For alarms with "DB" or "EDB", it stops with the dynamic brake without forced stop deceleration.