JAE MX19/MX19A Series Connector Handling Manual

This document provides the handling on MX19 / MX19A series connectors


JAE MX19/MX19A Series Connector Handling Manual - cover page
Brand
JAE
Category
Other Electronics
Document type
User Manual
Language
English
Pages
15
File format
PDF
File size
598 KB
Published
26 October, 2023
Updated
26 October, 2023
Model
MX19
MD5 checksum
5902F2BA2ACA28C5C6E276A66540F501

About this manual

This JAE handling manual provides handling instructions for MX19/MX19A series connectors. It covers crimping contacts, inserting contacts and dummy plugs, withdrawing contacts, and engaging or separating connectors.

The document lists applicable housings, contacts, dummy plugs, and wire types, gives crimp height criteria and defective workmanship examples, and includes cautionary statements for safe handling.

What's inside

  • Purpose
  • Applicable items
  • Crimping
  • How to insert
  • How to withdraw contact
  • How to engage/separate connector
  • Cautionary statement

Specifications

Applicable wire typesCAVS 0.3mm2, CPTL 22, CAVS 0.5mm2, AVSS 0.3mm2, AVSS 0.5mm2, FLRY-B 0.5mm2, FLRY-A 0.35mm2, FLRY-B 0.35mm2
Crimp height CAVS 0.3mm20.73~0.83 mm
Crimp height CAVS 0.5mm20.75~0.85 mm
Dummy plug end-face tolerance0 +0.5/-0.5 mm
Bend-up limit pin contact< 0.1 mm

Frequently asked questions

What wires can be used with MX19/MX19A connectors?

CAVS 0.3mm2, CPTL 22, CAVS 0.5mm2, AVSS 0.3mm2, AVSS 0.5mm2, FLRY-B 0.5mm2, FLRY-A 0.35mm2, and FLRY-B 0.35mm2 are listed as applicable wires.

How do you separate an engaged MX19 connector?

Hold the socket housing and pull the connector straight out while depressing the lock arm to release the engagement lock.

What is the proper crimp height for CAVS 0.3mm2 wire?

The appropriate crimp height is 0.73 to 0.83 mm.