This file is the Advantage® Compact Stainless Actuator user manual, which introduces the usage instructions and maintenance methods
This is the Installation, Operation, and Maintenance Manual for the ITT Advantage Compact Stainless Actuator, an actuator designated by the model code ACS. The manual opens with safety message levels, user health and safety precautions, and transportation and storage guidelines, then describes how the actuator is identified on the ITT identification tag and how ACS model numbers are built from the mode of operation.
The installation and maintenance section covers precautions, installing the valve and topworks, changing the compressor, tube nut, and snap ring, mounting the topworks to the valve, tightening the bonnet fasteners, the fastener torque table, actuator operating pressure, inspection, disassembly, and diaphragm replacement. A parts listing and cross-sectional drawings for the ACS actuator close the document.
| Maximum recommended actuation pressure | 90 PSI (6.2 Bar) |
|---|---|
| Actuator model code | ACS - Advantage Compact Stainless actuator |
| Autoclave temperature limit | 134°C | 273°F |
| PTFE diaphragm thermal decomposition temperature | 380°C | 716°F or greater |
It identifies an Advantage Compact Stainless actuator that is fail close with a 90# spring.
The model number is on the ITT identification tag.
No. It should not be disassembled because of live spring loads; only the compressor and diaphragm attachment systems have serviceable parts.
It is not intended for submersion, and clean out of place processes should be limited to wipe down procedures.