This manual introduces the features and usage methods of the Ersa EASY ARM 2 welding smoke extractor.
This manual provides instructions for the Ersa EASY ARM 2, a compact and powerful welding fume extractor designed for use in production, design, and laboratory environments. The device features a flexible plug-in system for extractors and hoods, allowing adaptation to different work areas. It utilizes a two-stage filtration process involving a pre-filter and a combined filter with HEPA and activated carbon to capture particles and absorb harmful gases. This manual is written in Spanish.
| Dimensions (H x W x D) | 470 mm x 255 mm x 490 mm |
|---|---|
| Weight | 15 kg |
| Noise level | 50 dB (A) |
| Air volume per connection | 2 x 110 m³/h |
| Minimum pressure | 2 x 1800 Pa |
| Filter class | F7 pre-filter / H13 Combined |
| Power consumption | 100 W |
| Voltage | 100-240 V AC |
The air temperature in the gas filter should be below 38 °C for optimal gas filtration.
The relative humidity must be kept below 60 % RH for optimal gas filtration.
No, the fume extraction device must not be used for the extraction of combustible gases.