This document is the Thermo Fisher Scientific AutoXP Installation Guide, which introduces the product's usage methods, safety precautions, installation methods, etc.
This manual provides installation instructions for the Thermo Fisher Scientific AutoXP, a compact explosion-proof flow computer designed for gas and liquid applications. It covers safety precautions, specific conditions of use, and general wiring requirements to ensure safe operation in hazardous environments.
| System | 32-bit, 60 MHz micro computer unit |
|---|---|
| SRAM memory | 2 MB, battery backed |
| Operating Temperature Range | -40°C to +85°C (-40°F to +185°F) |
| Power Supply | Standard 10–30 Vdc Class 2 power circuit |
| Safety Listing | CSA: C/US Class I, Div. 1, Groups B, C & D, T5 |
Do not open when an explosive atmosphere is present, and use suitably rated entry devices for cable transfer.
Required tools include a flat head screwdriver, ¼” wrench, 3/8” wrench, 3/64” Allen wrench, and 1.5 mm Allen wrench.
Conduit sealing devices must be installed within 50mm of the enclosure for cable transfer via conduit.