Fisher 1B and 1BR Constant-Pressure Pump Governor Actuators Instruction Manual

This document is an instruction manual for the Fisher 1B pump governor actuator. The manual provides detailed information on installation, adjustment, maintenance and parts ordering.


Fisher 1B and 1BR Constant-Pressure Pump Governor Actuators Instruction Manual - cover page
Brand
Fisher
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
100 KB
Published
20 October, 2023
Updated
20 October, 2023
MD5 checksum
2C06F3CB67C80267A1E26FDA052E33AC

About this manual

This instruction manual provides information on the installation, adjustment, maintenance, and parts ordering for the Fisher 1B and 1BR constant-pressure pump governor actuators. The 1B model is a direct-acting actuator used with push-down-to-close valves, while the 1BR is a reverse-acting actuator designed for use with push-down-to-open valves as a relief governor. These actuators are intended for maintaining constant discharge pressure on steam-driven turbine or reciprocating pumps in applications such as fire pumps, boiler feedwater pumps, and industrial or refining pumps.

What's inside

  • Introduction
  • Description
  • Specifications
  • Installation
  • Adjustments
  • Maintenance
  • Parts Ordering
  • Parts List

Specifications

Maximum Cylinder Pressure48.3 bar (700 psi)
Effective Piston Area45 cm2 (7.07 square inches)
TravelUp to 19.1 mm (0.75 inch)
Cylinder Cap and Yoke MaterialCast iron
Piston MaterialBrass, chrome-plated
Maximum Cylinder Operating Temperature130 C (265 F) or 66 C (150 F) for leakfree service

Frequently asked questions

What is the difference between the Fisher 1B and 1BR actuators?

The 1B is direct-acting with increased control pressure closing valves, while the 1BR is reverse-acting with increased control pressure opening valves.

Can the Fisher 1B actuator be installed below the line?

Yes, it can be installed either above or below the line, but it is recommended to install it above the line if possible.