This manual describes the technical features and operation of the R&S®TLx9 transmitter system.
This manual provides detailed instructions for installing, operating, and maintaining the R&S®TLx9 transmitter system. It covers safety guidelines, system design, module configurations, and technical specifications for both 1HU (15/10/5 W) and 2HU (200/100/50/25 W) models. Sections include redundancy systems, interface descriptions, and power requirements.
The document also includes safety warnings for RF radiation, AC power hazards, and high-energy circuits. It specifies compliance with standards like ETSI EN 300 744 and ETSI EN 302 755 for DVB-T and DVB-T2, and provides detailed interface tables for ASI and RF connections.
| Frequency Range | 470 MHz to 790 MHz |
|---|---|
| Channel Bandwidth | 6, 7, or 8 MHz |
| RF Output Power Stability | ±0.253 dB (±6%) |
| Max Installation Altitude | 2000 m (above sea level) |
| Operating Temperature | +1 °C to +45 °C |
| Power Supply Voltage | 100 to 240 V AC ± 10 % |
| Power Consumption | 200 W (DTV average power: ~800 W) |
The 1HU model has power ratings of 15/10/5 W, and the 2HU model has ratings of 200/100/50/25 W.
It complies with ETSI EN 300 744, ETSI EN 302 755, ARIB STD-B31, and ABNT NBR 15601 for DVB-T, DVB-T2, and ISDB-T.
The maximum installation altitude is 2000 meters above sea level.
The operating temperature range is +1 °C to +45 °C (technical data guaranteed).