This manual provides safety instructions for using the R5020 AC clamp meter, product features, specifications, instrument description, operating instructions, etc.
This is the instruction manual for the Reed Instruments R5020 AC clamp meter. It provides safety warnings, detailed specifications, and step-by-step operating instructions for measuring AC current, voltage, resistance, capacitance, temperature, diode, and continuity. The manual also covers non-contact voltage detection, data hold, relative mode, and battery replacement. It includes safety precautions and usage guidelines to prevent damage or injury.
| AC Current Range | 40.00, 400.0A |
|---|---|
| AC Current Accuracy | ±(2.5% rdg. + 8 dgt.) |
| DC Voltage Range | 400.0mV, 4.000, 40.00, 400.0, 600.0V |
| DC Voltage Accuracy | ±(1.5% rdg. + 2 dgt.) |
| AC Voltage Range | 4.000, 40.00, 400.0, 600.0V |
| AC Voltage Accuracy | ±(1.8% rdg. + 8 dgt.) |
| Resistance Range | 400.0Ω, 4.000, 40.00, 400.0kΩ, 4.000, 40.00MΩ |
| Resistance Accuracy | ±(1.5% rdg. + 2 dgt.) |
| Capacitance Range | 40.00, 400.0nF, 4.000, 40.00, 100.0µF |
| Capacitance Accuracy | ±(3% rdg. + 5 dgt.) |
| Temperature Range | -20.0 to 760.0°C (-4.0 to 1400.0°F) |
| Temperature Accuracy | ±(3% rdg. + 5°C/9°F) |
| Jaw Opening | 1.2” (30mm) maximum |
| Power Supply | 2 x 1.5V “AAA” batteries |
| Dimensions | 200 x 66 x 37mm |
| Weight | 205g |
The AC current range is 40.00A to 400.0A.
The temperature range is -20.0°C to 760.0°C (-4.0°F to 1400.0°F).
It uses 2 x 1.5V “AAA” batteries.
Set the function switch to the 400 or 40A range, press the trigger to open the jaw, and fully enclose one conductor.