Moog MSD Servodrive 2 Analog Output Function Description

This document describes the 2 analog output functions of moog MSD Servodrive series products


Moog MSD Servodrive 2 Analog Output Function Description - cover page
Brand
MOOG
Category
Industrial Robot
Document type
Datasheet
Language
English
Pages
6
File format
PDF
File size
1.8 MB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
62725A463BB9F614CB73BC69DDF52043

About this manual

This document details the function and technical specifications of the two analog outputs (OEA00 and OEA01) on Moog's MSD Servodrive. It covers selectable actual value outputs, scaling, offset, and filtering. The analog outputs support a ±10 V range with 12-bit resolution and are short-circuit protected. Terminal assignments and parameter settings for configuration are provided. This document does not replace the main operation manual and is intended for technical reference only.

The document includes technical data such as maximum voltage, output current, update cycle, and capacitance limits. It also specifies parameter settings for offset, scaling, and filtering, which can be adjusted via the controller’s parameters. The document is applicable from firmware version V1.1 and is subject to change without notice.

What's inside

  • Analog Outputs
  • Technical Data
  • Parameter Settings
  • Terminal Assignments
  • Filtering and Scaling

Specifications

Number of Channels2 channels
Accuracymax. +/- 2 % referred to 10 V
Max. Voltage+/- 10 V, differential U max: +/- 12,5 V
Max. Output Current5,0 mA at 10 V, short-circuit-proof
Update CycleCorresponding to the clock frequency of the power stage (default 8 KHz)

Frequently asked questions

What are the selectable actual value outputs for the analog outputs?

The analog outputs can transmit actual speed, actual torque/force, RMS current, or a defined parameter value.

What is the voltage range for the analog outputs?

The analog outputs support a ±10 V range with a maximum differential voltage of ±12.5 V.

What is the filter time setting for noise suppression?

The filter time is set via parameter P0133, with values in milliseconds for each output.

Download PDF (1.8 MB)

More MOOG Manuals