Thermo Fisher Scientific 21658 Undercounter & Mid-Size Control Room Temperature with Temp Display System User Manual

This manual is the owner's guide for Undercounter & Mid-Size Control Room Temperature with Temp Display System, which introduces the product's receiving, installation, operation, troubleshooting, maintenance and cleaning.


Thermo Fisher Scientific 21658 Undercounter & Mid-Size Control Room Temperature with Temp Display System User Manual - cover page
Brand
Thermo Fisher Scientific
Category
Refrigerators
Document type
User Manual
Language
English
Pages
18
File format
PDF
File size
266 KB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
2E7F8DE0578FFEF74E18520D39591916

About this manual

This manual provides instructions for installing, operating, and maintaining the Thermo Fisher Scientific 21658 undercounter and mid-size temperature control system. It includes safety guidelines, electrical requirements, setup procedures, and temperature control settings. The system is designed for scientific and medical applications, with features like a digital microprocessor controller, alarm functions, and adjustable temperature settings. Maintenance and troubleshooting steps are also covered.

The manual emphasizes safety precautions, such as avoiding storage of flammable or corrosive materials, proper grounding, and correct electrical connections. It also includes detailed steps for leveling the unit, installing wire shelves, and installing field monitor probes. Temperature settings are factory-set for optimal performance, and users are advised to consult technical support before making adjustments.

What's inside

  • Receiving and Shipping Damage Handling
  • Safety
  • Electrical Information
  • Installation
  • Operation
  • Quick Troubleshooting Guide
  • Maintenance and Cleaning
  • Hydrocarbon Service Notes
  • Factory Warranty Policy

Specifications

Supply VoltageMust conform to NEC (National Electrical Code)
Temperature RangeFactory set to operate at ultimate temperature performance
Set Point21°C or 70°F (cabinet)

Frequently asked questions

What is the factory-set temperature range for this unit?

The unit is factory-set to operate at its ultimate temperature performance. Adjusting settings may alter these factory settings.

What safety precautions should I take when using this unit?

Do not store unsealed chemical materials, gasoline, or flammable liquids in the cabinet. Do not operate in the presence of explosive fumes. Ensure proper grounding and avoid using GFI circuits or extension cords.

How do I level the unit?

Set a leveler on each corner of the top. Adjust the leveling legs or casters if the unit is not level. It is recommended to tilt the unit slightly toward the back (about 5 degrees) to ensure proper door closure and condensate drainage.

What should I do if I receive a damaged unit?

For visible damage, note it on the delivery receipt and take pictures. For concealed damage, stop unpacking, retain all packing materials, take pictures, and contact the carrier immediately. Do not return the unit to the manufacturer.