This document introduces the use of torque sensor T5, including measuring characteristics, mounting, measurement of dynamic torques, protective precautions, maintenance and servicing, and electrical connection.
The HBM T5 Torque Transducer Operating Manual (document B 23.T5.21) provides instructions for the T5 torque flange, intended for torque measurement and directly related control and regulation tasks only. It covers appropriate use, safety symbols, qualified personnel, and warranty conditions.
Topics include measuring characteristics, mounting position and housing fastening, load capability, dynamic torque measurement, IP50 protection precautions, maintenance of slip rings and carbon brushes, electrical connection, accessories, technical data, and dimensions.
| Sensitivity | 2mV/V |
|---|---|
| Rated supply voltage | 0.5V...12V |
| Input resistance | 350 Ω |
| Protection class | IP50 to EN 60 529 |
| Static overload limit | max. 50% of nominal torque |
The torque transducers T5 are designed in protection class IP50 to EN 60 529.
The nominal torques may be statically exceeded by max. 50%.
Replacement of the carbon brushes can only be carried out in the factory at Darmstadt.
The sensitivity is 2mV/V.