This manual describes the function, connections and operation of the PME-MP55 module.
This manual provides instructions for operating and setting up the HBM PME-MP55 module, a carrier-frequency amplifier for connecting various transducers. It covers safety guidelines, DIP switch configuration, installation, connections, and CAN interface setup. The module operates with a 18–30 V DC supply and supports CANopen communication. Maintenance is maintenance-free, and cleaning requires disconnecting power and using a damp cloth without solvents.
The manual includes detailed sections on commissioning, parameter assignment, error messages, and technical specifications. It also explains how to use the PME Assistent software for parameter configuration and provides safety warnings for proper installation and operation.
| Supply Voltage | 18 to 30 V DC |
|---|---|
| Protection Rating | IP20 |
The MP55 module must be operated with an extra-low safe voltage (supply voltage 18 to 30 V DC).
DIP switches are used to set bridge excitation voltage, effective range, bridge type, analogue output, master/slave, terminating bus impedance, and edge steepness. They must be set before fitting the module.
The MP55 module is protected against direct contact with water (IP20).