This is a product manual, which mainly introduces the product's use methods, installation methods, technical specifications and other information
This manual applies to the ME - M7 Performance Level “c” series produced by Gefran spa. Gefran melt pressure sensors with amplified electrical output are designed to measure the pressure and temperature of melted plastic at different temperatures according to the filling fluid used; the correct temperature range is 400°C.
The document covers general information, mechanical dimensions by reference to product datasheets or the Gefran website, installation and positioning, installation seat preparation and checks, wiring and calibration, NE21/NE43 compatibility, sensor technical specifications, transport, storage and disposal, safety, and a safety manual for Performance Level “c” sensors. It states that installation and/or maintenance workers must read the manual and follow its instructions.
| Correct temperature range | 400°C |
|---|---|
| Recommended installation torque | 50 Nm (maximum 56.5 Nm) |
| Mounting thread options | 1/2-20UNF, M18x1.5 |
The manual states a correct temperature range of 400°C.
A torque of 50 Nm is recommended; the maximum is 56.5 Nm.
Yes. The manual says the ME and M7 series are fully compatible with the NE21 and NE43 Namur recommendations.
The hole must be completely clean and free of any plastic residual.