Gefran ME M7 Performance Level c Melt Pressure Sensor Instruction Manual

This is a product manual, which mainly introduces the product's use methods, installation methods, technical specifications and other information


Gefran ME M7 Performance Level c Melt Pressure Sensor Instruction Manual - cover page
Brand
GEFRAN
Category
sensor
Document type
User Manual
Language
English
Pages
28
File format
PDF
File size
816 KB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
52D9E26D1F10EF3471F2D7C7AEC61275

About this manual

This manual applies to the ME - M7 Performance Level “c” series produced by Gefran spa. Gefran melt pressure sensors with amplified electrical output are designed to measure the pressure and temperature of melted plastic at different temperatures according to the filling fluid used; the correct temperature range is 400°C.

The document covers general information, mechanical dimensions by reference to product datasheets or the Gefran website, installation and positioning, installation seat preparation and checks, wiring and calibration, NE21/NE43 compatibility, sensor technical specifications, transport, storage and disposal, safety, and a safety manual for Performance Level “c” sensors. It states that installation and/or maintenance workers must read the manual and follow its instructions.

What's inside

  • General information
  • Mechanical dimensions
  • Installation and positioning on the machine
  • Installation seat
  • Wiring and calibration
  • NE21 and NE43 compatibility
  • Sensor technical specifications
  • Transport, storage and disposal
  • Safety
  • Safety Manual for Performance Level “c” sensors

Specifications

Correct temperature range400°C
Recommended installation torque50 Nm (maximum 56.5 Nm)
Mounting thread options1/2-20UNF, M18x1.5

Frequently asked questions

What temperature range should the melt pressure sensors be used with?

The manual states a correct temperature range of 400°C.

What torque is recommended when installing the transducer?

A torque of 50 Nm is recommended; the maximum is 56.5 Nm.

Are the ME and M7 series compatible with NE21 and NE43?

Yes. The manual says the ME and M7 series are fully compatible with the NE21 and NE43 Namur recommendations.

What should be checked before installing a sensor in a previously used hole?

The hole must be completely clean and free of any plastic residual.